電站測溫用熱電阻
WZC-130B,WZP-220B,WZP-221B,WZP-230B,WZP-231B,WZP2-220B,WZP2-221B,WZP2-230B,WZP2-231B,WZP-220AB,WZP2-220AB。WZC-220B,WZC-230B,WZC-220AB,WZP-320B,WZP-321B,WZP-330B,WZP-331B,WZP2-320B,WZP2-321B,WZP2-330B,WZP2-330B,WZC-320B,WZC-320B,WZP-420B,WZP-421B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZC-420B,WZC-430B,WZP-420B,WZP-421B,WZP-430B,WZP-430B,WZP-431B,WZP2-420B,WZP2-421B,WZP2-430B,WZP2-431B,WZP-42AB,WZP2-42AB,WZP-420B,WZC-430B,WZP-621B,WZP-621AB,WZP-631B,WZP2 -621B,WZP2 -621B,WZP2 -631B,WZP-621B,WZP-631B,WZP-621B,WZP2 -631B,WZP-621AB,WZP2-621AB,WZP-002,WZP-003,WZP-003A,WZCM-201,WZPM-201,WZPM-201,WZP-270S,WZP-26S,WZP-236SB,
量程規格
名稱
|
分度號
|
測溫范圍℃
|
精度等級
|
允差Δt
|
鎳鉻-鎳硅熱電偶
|
K
|
0~800
|
2
|
±2.5℃或 ±0.75%t
|
鎳鉻-銅鎳熱電偶
|
E
|
0~600
|
2
|
±2.5℃或 ±0.75%t
|
鉑熱電阻
|
Pt100
|
-200~500
|
B
|
±(0.3+0.005|t|)
|
注:t為感溫元件實測溫度或實測溫度的絕對值。
□公稱壓力
一般是指在常溫下,保護管所能承受的靜態外壓而不破裂,試驗壓力一般采用公稱壓力的1.5倍。實際上,允許工作壓力不僅與保護管材料、直徑、壁厚有關,而且還與其結構形式、安裝方法、置入深度以及被測介質的流速、種類有關。
□熱電偶絕緣電阻
常溫絕緣電阻的試驗電壓為直流500V。測量常溫絕緣電阻的大氣條件為:溫度15~35℃,相對濕度45%RH,大氣壓力86~106kPa。
對于長度超過1米的熱電偶,它的常溫絕緣電阻值與其長度的乘積應不小于100MΩ•m,
即:Rr•L>100MΩ•mL>1m
式中:Rr-熱電偶的常溫絕緣電阻值,MΩ;
L-熱電偶的長度,m。
對于長度等于或不足1米的熱電偶,它的常溫絕緣電阻值應不小于100MΩ。
□熱電阻絕緣電阻
常溫絕緣電阻的試驗電壓可取直流10~100V任意值,環境溫度應在15~35℃范圍內,相對濕度應不大于80%RH,常溫絕緣電阻值應不小于100MΩ。
□熱電阻允許通過電流
通過鉑電阻的測量電流最大不超過5mA。
滅菌器YXQ-LS-50A 滅菌器YXQ-LS-100SII 滅菌器YXQ-LS-75SII 滅菌器YXQ-LS-50SII 滅菌器YXQ-LS-30SII 滅菌器YXQ-LS-18SI 滅菌器YXQ-SG46-280S 滅菌器YXQ-SG46-280SA 滅菌器LDZH-200KBS 滅菌器JDZH-150KB5 滅菌器LDZH-100KBS 滅菌器LDZM-80KCS 滅菌器LDZM-60KCS 滅菌器LDZM-40KCS 滅菌器LDZX-50FBS 滅菌器LDZX-50FB 滅菌器LDZX-50FAS 滅菌器LDZX-50FAS 滅菌器LDZX-50FA 滅菌器LDZX-30FBS 滅菌器LDZX-30FB 滅菌器LDZX-30FAS 滅菌器LDZX-30FA 滅菌器LDZX-75KBS 滅菌器LDZX-75KB 滅菌器DZX-75KAS 滅菌器LDZX-50KBS 滅菌器LDZX-50KB 滅菌器LDZX-50KAS 滅菌器LDZX-30KBS 滅菌器SYQ-DSX-280C 滅菌器SYQ-DSX-280B 滅菌器SYQ-DSX-280A 離心機LD-5 離心機LD-4 離心機LD-3 離心機80-3 離心機TGL-16 離心機YXJ-2 離心機YXJ-1 離心機YXJ-1 離心機80-2 離心機80-1 離心機800 離心機CL-36KT-A 離心機CL-32K-A 離心機GL-21C 離心機GL-20G-C 離心機GL-20G-C 離心機GL-12C 離心機DL-6000C 離心機DL-5000C 離心機DL-4000C 離心機LXJ-IIC 離心機TGL-20000-CR 離心機TGL-18000-CR 離心機TDL-5000-CR 離心機TGL-20B-C 離心機TGL-18C 離心機TGL-10C 離心機TDL-60C 離心機TDL-5C 離心機TDL-50C 離心機TLXJ-IIC 離心機TDL-36C 離心機TDL-40C 離心機TDL80-2C 離心機KA-1000C 離心機TDL-4C 離心機GL-20B 離心機GL-21B 離心機GL-12B 離心機GL-16G-II 離心機GL-20G-II 離心機DDL-5 離心機DL-4000B 離心機DL-5000B 離心機DL-6000B 離心機DL-5-B 離心機LXJ-IIB 離心機TGL-16GR 離心機TGL-16AR 離心機TGL-20BR 離心機TDL-5000BR 離心機TGL-10B 離心機TGL-20B 離心機TDL-5 離心機TDL-5-A 離心機TDL-40B 離心機TDL-60B 離心機TGL-12B 離心機TDL-4 離心機KA-1000 離心機TDL-80-2B 離心機ZD-2 離心機800B 離心機80-2B 離心機80-2C 離心機MLX-1000 離心機TGL-16G 離心機TGL-16C 離心機TGL-16B 離心機TGL-16M |